Mass Systemswitch 16 kW (230 V)
Mass Systemswitch: The complete system solution
  • Three AC inputs, for example inverter, grid power and generator.
  • Three or four outlets to AC power groups.
  • Automatic switching.
  • Power transfer from 4.5 kW to 16 kW, input/output from 25 to 63 A.
  • Information source for central energy management via MasterBus network.
  • Optional automatic fuses; for larger systems this usually requires an extra casing.
  • MasterBus compatible.
Suitable for MasterBus

As the Mass Systemswitch is suitable for MasterBus, all the information can also be read out on, for instance, a MasterView display, including the status of the charge current and the inverter.

LED indications on Systemswitch

Read out of the basic functions on the display, including indication of available power source, generator, grid power or inverter and load on inverter' function.

Central energy management

The MasterView Easy indicates AC current, amperage and frequency including the load on inverter' mode. The 12/24 V read out shows current, power (charge/discharge) and battery monitoring, and has a start/stop generator.

Smart electronics

The intelligent electronics control the switching to ensure that the equipment does not use too much power. Its double pole relay is sustainable and incredibly safe. 

Specifications:
General specifications
Nominal input voltage230 V (50/60 Hz)
Input voltage range200-250 V
Number of inputs3
Number of outputs4
Dimensions, hxwxd 340 x 261 x 144 mm
13.4 x 10.3 x 5.7 inch
Weight 5 kg
11.0 lb
 
Technical specifications
Connection for remote controlyes
LED indication on enclosureindication voltage sources present and 'load on inverter' mode
Nominal input current generator63 A
Nominal input current grid40 A
Nominal input current inverter25 A
Earth leakage protectionno
Generator input switchcont. monitoring of voltage and frequency
Time delay generator input0-10 sec (adjustable)
Nominal current shortbreak output25 A
Nominal current power output40 A
Nominal current generator output63 A
Automatic circuit breakersno, system dependent
Power consumption (AC all inputs)33 W
Power consumption (only inverter power)< 1 W
Transfer timeswitch on 12-22 ms / switch off 4-19 ms
Temperature range (specified) -5 degreesC to 60 degreesC
23 degreesF to 140 degreesF
Temperature range (ambient temp.) -25 degreesC to 70 degreesC
-13 degreesF to 158 degreesF
Temperature range (storage/non operating) -60 degreesC to 80 degreesC
-76 degreesF to 176 degreesF
Relative humiditymax. 95% (non condensing)
Frequency watchyes
Cable size0.5-10 mm/AWG 20-7, remote control 0.14-2.5 mm/AWG 26-13
Protection degreeIP23
MasterBus compatibleyes
 
 