General specifications |
Output voltage | 100/110/115/120 V - 50/60 Hz (selectable) |
Output waveform | true sine |
Nominal battery voltage | 24 V |
Recommended battery capacity | ? 50 Ah |
Continuous power at 25 degreesC / 77 degreesF, cos phi 1 | 700 W |
Continuous power at 40 degreesC / 104 degreesF, cos phi 1 | 700 W |
Peak load (1 min.) | < 810 W |
Peak load (1 s) | < 1230 W |
AC connection | North American socket with GFCI |
Galvanic isolation | yes |
Efficiency | 93 % |
Display/read-out | LED indication: battery voltage, load level, status |
Alarms | potential free alarm contact |
Dimensions, hxwxd | 200 x 330 x 83 mm 7.9 x 13.0 x 3.3 inch |
Weight | 2.6 kg 5.7 lb |
Compliance | safety: UL 458, EMC: FCC class B |
|
Technical specifications |
Technology | high frequency, input and output fully isolated |
Low battery voltage, switches off at | 21 V |
Low battery voltage, switches on at | 25 V |
High battery voltage, switches off at | 33 V |
High battery voltage, switches on at | 29 V |
Input current (nominal load) | 35 A |
No-load power consumption (ON mode) | < 0.8 A |
No-load power consumption (energy saving mode) | < 0.06 A |
Minimal DC fuse (slow blow) | 50 A |
Minimal cable size | 16 mm |
Harmonic distortion typical | < 5 % |
Cos phi | all power factors allowed |
Temperature range (ambient temp.) | -20 degreesC to 60 degreesC, derating power > 40 degreesC -4 degreesF to 140 degreesF |
Cooling | temperature and load controlled fan |
Protection degree | IP21, horizontal wall mounting |
Protections | over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) |
MasterBus compatible | yes, using a MasterBus AC Master Interface |
|
|